Session Program

HOME » Program » Session Program

Date & Time

Wednesday, 24th April from 9:00 - 17:00 hrs.
Thursday, 25th April from 9:00 -16:30 hrs.

Venue

Room1(鳳凰- Hoh-oh -), Room2(白凰- Hakuho -)& 2nd Floor Lobby

Program & Time Schedules

Wednesday, 24th April

Time Oral Session Poster Session
Room1 (鳳凰- Hoh-oh -) Room2 (白凰- Hakuho -) 2nd Floor Lobby
09:00 ~ 10:30 Opening Session
10:30 ~ 11:00 Coffee Break
11:00 ~ 12:30 Session 1 : Common Session
12:30 ~ 13:30 Lunch Poster 1
[Time Schedule]
13:00 – 16:50

[Category]
B2,D1
13:30 ~ 15:00 Session 2 : CIGRE A3
Transmission and
Distribution Equipment
Session 4 : CIGRE B3
Substations and Electrical
Installations
15:00 ~ 15:30 Coffee Break
15:30 ~ 17:00 Session 3 : CIGRE A3
Transmission and
Distribution Equipment
Session 5 : CIGRE B4
DC Systems and Power
Electronics

Thursday, 25th April

Time Oral Session Poster Session
Room1 (鳳凰- Hoh-oh -) Room2 (白凰- Hakuho -) 2nd Floor Lobby
09:00 ~ 10:30 Session 6 : CIGRE B2
Overhead Lines
Session 9 : CIGRE A2
Power Transformers and
Reactors
Poster 2
[Time Schedule]
9:00 – 12:50

[Category]
A3, B1, B3, B4, C4
10:30 ~ 11:00 Coffee Break
11:00 ~ 12:30 Session 7 : CIGRE B2
Overhead Lines
Session10 : CIGRE D1
Materials and Emerging
Test Techniques
12:30 ~ 13:30 Lunch
13:30 ~ 15:00 Session 8 : CIGRE C4
System Technical
Performance
Session11 : CIGRE B1
Insulated Cables
15:00 ~ 15:30 Coffee Break
15:30 ~ 16:30 Closing Session

Opening Session

 

【Room 1 + Room 2】Wednesday, 24th April 9:00 ~ 10:30
Facilitator: Taku Yamakawa

Technical Session

Session 1

Common Session

【Room 1 + Room 2】Wednesday, 24th April 11:00 ~ 12:30
Session Chair: Konstantin O. Papailiou   Secretary: Hiroki Ito

1-1 The Voltage-Sourced Converter applied to New Hokkaido-Honshu HVDC Link
T. ARAI, S. NAOI, D. SUZUKI, T. MURAO, N. KAWAKAMI, K. USUKI, K. KASHIWAGI, A. MIURA
1-2 Live line maintenance in HVDC ± 800 KV- minimum safety distance and minimum number of insulators in good condition
J. CARDOSO, A. NIGRI, C. OLIVEIRA
1-3 Direct Current High-Voltage Gas-Insulated Switchgear up to ±550 kV
H. KOCH, M. HERING, K. JUHRE
1-4 Application Strategies for Externally Gapped Line Arresters Against Lightning Outages on the 400 kV Overhead Transmission Lines in Hong Kong
K. VELITSIKAKIS, C. ENGELBRECHT, S. LAU, W. CHEUNG
1-5 Development and Experience of Proficiency Test Scheme for High Voltage Testing
T. WAKIMOTO, S. MIYAZAKI, M. ISHII, T. BANNO, E. HINO, H. WADA, J. KIDA

Session 2

CIGRE A3 : Transmission and Distribution Equipment

【Room 1(鳳凰 - Hoh-oh -)】Wednesday, 24th April 13:30 ~ 15:00
Session Chair: Nenad Uzelac   Secretary: Daisuke Yoshida

2-1 Development of EHV DC circuit breaker with current injection
S. TOKOYODA
2-2 UFD with High Arc Resistance and Dielectric Recovery Characteristics for Current Commutated Hybrid DCCB
K. KANAYA
2-3 Development of 250 kV DC Gas Insulated Switchgear
Y. ABE
2-x4 Optimizing the Protection Level of Surge Arrester in HVDC Converter Station by Increasing the charge rate of the ZnO varistors
X. ZHAO
2-5 Improvement of high energy absorption capability of ZnO element and its application for transmission line arresters with externally series gap
Y. AKA

Session 3

CIGRE A3 : Transmission and Distribution Equipment

【Room 1(鳳凰 - Hoh-oh -)】Wednesday, 24th April 15:30 ~ 17:00
Session Chair: René Smeets   Secretary: Daisuke Yoshida

3-1 Recovery Voltage at Capacitive Current Interruption for High Resistance Earthed Neutral Systems
M. TOYODA
3-2 Design Optimization of 126kV Axial Magnetic Field Contact
Z. WANG
3-3 Research on Temperature Field Simulation Technology of Vacuum Circuit Breaker Based on Multi-physics-field Coupling
Z. WANG
3-4 High Voltage F-gas Free Switchgear Applying CO2/O2 Sequestration with a Variable Pressure Scheme
D. SCHIFFBAUER
3-5 Investigation of thermal interrupting performance of a circuit breaker with SF6 and SF6 alternatives
M. SATO

Session 4

CIGRE B3 : Substations and Electrical Installations

【Room 2(白凰 - Hakuho -)】Wednesday, 24th April 13:30 ~ 15:00
Session Chair: Koji Kawakita   Secretary: Mark Osborne

4-1 UHV AC Substation Design Standardization
K. UEHARA, G. SUN, Y. ZHANG, S. TSUKAO, R. HEMMI, T. SAIDA
4-2 Long-term qualification procedure on a GIS HVDC RC-divider and HVDC GIS system up to ±350 kV
U. RIECHERT, E. SPERLING
4-3 Design and test of a 1100kV GIL for tunnel installation
H. -D. SCHLEMPER, Q. LIU, H. SHEN
4-4 Challenges for Compact Gas Insulated Substation Considering Reduction of Environmental Impact, Fire Prevention and Safety
I. YOSHIDA, S. TSUKAO, B. KANI
4-5 Application of polymeric gas bushing for transformer to improve the reliability, safety and maintainability in substation
K. ITO, K. SASAMORI, S. TSUKAO, A. TAGEI, S. IWASAKI, M. NAKAI, M. KATSUMATA, T. GOTO

Session 5

CIGRE B4 : DC Systems and Power Electronics

【Room 2(白凰 - Hakuho -)】Wednesday, 24th April 15:30 ~ 17:00
Session Chair: Mohamed Rashwan   Secretary: Hiroyuki Furukawa

5-1 Power System Coherency Identification for Large HVDC-AC Grids
A. M. KHALIL, R. IRAVANI
5-2 A New Energy Management Control of Modular Multilevel Converters for Coping with Voltage Stress on Sub-Modules
K. SHINODA, A. BENCHAIB, J. DAI
5-3 Impact of Operational Parameters on HVDC Circuit Breaker Requirements
M. ABEDRABBO, W. LETERME, D. V. HERTEM
5-4 Design and Development of Ultrafast Mechanical Switch for 500kV Hybrid DC Circuit Breaker
K. SUN, Y. WEI, J. ZHONG, S. TAN, X. DUAN, L. XIE, Y. WEI
5-5 MMC-STATCOM application at Dominion Energy Colington substation
F. NAKAMURA, A. MATSUDA, T. TSUCHIYA, D. SULLIVAN, B. BUTERBAUGH, M. MCVEY

Session 6

CIGRE B2 : Overhead Lines

【Room 1(鳳凰 - Hoh-oh -)】Thursday, 25th April 9:00 ~ 10:30
Session Chair: Herbert Lugschitz   Secretary: Taku Yamakawa

6-1 New tools and technologies during high-voltage live-line maintenance
D. SZABÓ, B. NÉMETH, G. GÖCSEI, L. RÁCZ
6-2 Risk Quantification of Insulator Failure towards Improving Inspection Efficiency in Transmission Lines
S. TANIGUCHI, N. KISHIGAKI, H. HAMADA, M. MORI, S. KIUCHI, T. KITASHIMA
6-3 Corrosion Evaluation of ACSR (Aluminium Conductor Steel-Reinforced cable) Overhead Transmission Lines with ACM (Atmospheric Corrosion Monitor) Sensors in Coastal Areas and Foggy Mountainous Areas
K. YOSHINO, A. KUROKAWA, N. KISHIGAKI, T. TATSUOKA, T. OSONO, T. TSUYA, Y. SAITOU, M. YAMAZAKI, T. KITASHIMA
6-4 Conductor Stringing Electrical Safety for Overhead Lines
T. GILLESPIE
6-5 Engineering process and performance verification of installing LC Spiral Rods on overhead transmission line crossing highways in Canada
N. BOUIKNI, H. HOZUMI

Session 7

CIGRE B2 : Overhead Lines

【Room 1(鳳凰 - Hoh-oh -)】Thursday, 25th April 11:00 ~ 12:30
Session Chair: Herbert Lugschitz   Secretary: Taku Yamakawa

7-1 Comparison of physical and analytical methods for Dynamic Line Rating (DLR) calculations
D. SZABÓ, B. NÉMETH, G. GÖCSEI, L. RÁCZ
7-2 Use cases of dynamic line rating for optimized operation and planning of power transmission network
R. KUWAHATA, F. VASSORT
7-3 Approach to evaluate thermal stresses of high temperature low sag conductors' fittings
B. SOPPE, T. KRAMPERT, R. PUFFER
7-4 The First Generation of Synergic Overhead Transmission Lines Network
C. NASCIMENTO, J. ROSOLEM, C. HORTENCIO, D. DINI, L. OBARA
7-5 Spacer dampers for EHV transmission lines: Control of aeolian vibrations and subspan oscillations
P. VAN DYKE, V. CHARI

Session 8

CIGRE C4 : System Technical Performance

【Room 1(鳳凰 - Hoh-oh -)】Thursday, 25th April 13:30 ~ 15:00
Session Chair: Hideki Motoyama   Secretary: Yoshihiro Baba

8-1 Comparison of Voltage Rise at Transmission Towers Hit by Lightning Calculated by FDTD and Method of Moments
M. SAITO
8-2 Risk assessment of 500 kV surge arrester due to direct and multiple lightning strokes
T. TSUBOI, S. OKABE, I. YOSHIDA, T. MAEKAWA, S. TSUKAO
8-3 FDTD simulation of EHV transmission line faults caused by winter lightning at a mountainous region along the coast of the Japan sea
N. ITAMOTO, H. KAWAMURA, Y. BABA
8-4 Using mixture distributions to analyze overvoltage probabilities for different prefault conditions in an HVDC converter station
A. BILOCK, L. AREVALO, D. WU
8-5 Analysis of internal overvoltage and insulation coordination of electrode line in HVDC project
S. XIE, T. ZHU, S. CAO, N. JIANG, C. ZHANG, Y. ZHANG, H. HE

Session 9

CIGRE A2 : Power Transformers and Reactors

【Room 2(白凰 - Hakuho -)】Thursday, 25th April 9:00 ~ 10:30
Session Chair: Shin Yamada   Secretary: Kohei Yamaguchi

9-2 Vibration Phenomena in Oil-Immersed Transformers Generated by Load Current using Electromagnetic Force and Structural Analysis
Y. ITO
9-x3 Field Experience of Natural Ester Filled Transformer
R. SHINDE

Session 10

CIGRE D1 : Materials and Emerging Test Techniques

【Room 2(白凰 - Hakuho -)】Thursday, 25th April 11:00 ~ 12:30
Session Chair: Ralf Pietsch   Secretary: Tsuguhiro Takahashi

10-1 General overview of AC and DC current injection on high voltage potential for HVDC long-term tests
M. HALLAS, V. HINRICHSEN
10-2 Development tests, type tests, factory acceptance tests and on-site tests using modular and mobile DC test systems
R. PIETSCH, U. STEPHAN, M. FELK, TH. STEINER
10-3 An alternative approach to cable fault location in high voltage engineering
F. BÖHME, R. PIETSCH, M. BUSCHENDORF
10-4 Testing and long-term performance of gas-insulated systems for DC application
K. JUHRE, M. HERING
10-5 Basic phenomena in gas-insulated HVDC systems and adequate dielectric testing
C. NEUMANN, K. JUHRE, U. RIECHERT, U. SCHICHLER

Session 11

CIGRE B1 : Insulated Cables

【Room 2(白凰 - Hakuho -)】Thursday, 25th April 13:30 ~ 15:00
Session Chair: Roberto Gaspari   Secretary: Hideo Tanaka

11-1 Partial discharge inception characteristics of oil impregnated paper insulation System with Inserted Insulating Papers of Removed Oil-filled Cable
Y. AIHARA, T. NAKAMURA, Y. GOTO, Y. MAKINO, T. KURIHARA, T. TAKAHASHI, M. NAKADE
11-2 A Study on Observation of Light Emission of Partial Discharges and Bubbles in Oil Gap on Oil Impregnated Paper Insulation System
Y. MAKINO, T. KURIHARA, T. TAKAHASHI
11-3 Thermoelectric Vapor Chamber Smart Cooling System for EHV Power Cables in Underground Tunnels
A. GUREVICH, I. STEINER, E. HUANG
11-4 250kV HVDC XLPE Cable System in Undersea Tunnel between Hokkaido and Honshu in Japan
Y.TABITA, Y.SATO, O.SAITO, S.YAMAMOTO, K. SUZUKI
11-5 Development of Long-bodied Joints to Replace Existing Joints for 275 kV XLPE Cables
Y. GOTO, N. MASHIMO, S. YAMAMOTO, Y. IDA, K. SUZUKI

Closing Session

 

【Room 1 + Room 2】Thursday, 25th April 15:30 ~ 16:30
Facilitator: Taku Yamakawa

Poster Session

 

Poster 1 : Category B2, D1

【2nd Floor Lobby】Wednesday, 24th April 13:00 ~ 16:50

P1-01 Economic Weatherability Structure Design Using Operational and Structural Reliability Concept – A Case Study from Manitoba Hydro
C. WANG, H. BILESKY, J. KELL
P1-02 Development of Static Induction [SI] power supply system applied to LED source for low intensity obstacle light
H. SAKAI, Y. SUGIURA
P1-04 Investigation of Wind Turbine Wake Effects on Overhead Line Conductor Vibration
N. WILLIAMS, T. KAVANAGH, O. ARMSTRONG, P. PORTER, J. NOCTOR
P1-05 Advanced Maintenance of Transmission Steel Towers with Environmental Monitoring Data and Corrosion Rate Maps
T. TATSUOKA, A. KUROKAWA, K. YOSHINO, N. KISHIGAKI, T. OSONO,T. TSUYA, Y. SAITOU, M. YAMAZAKI, T. KITASHIMA
P1-06 Innovative methodology for modelling the criticality of shutdowns by fires in transmission line spans and optimum area design for the suppression of vegetation
A. BERREDO, A. SOUSA, C. RODRIGUES, L. ARASATO, D. PALOMO, A. SOUSA, F. COUTINHO
P1-08 Review of Lightning Performance of 500kV Air Tawar – Bukit Tarek/Janamanjung Overhead Transmission Line of Malaysia: An Insight into Efforts to Improve Line Performance Against Lightning
N. HUDI
P1-09 Insight into the Trending of Solar Radiation and Ambient Temperature in Malaysia towards a Possible Implementation on Step-Wise Rating.
C. FOON, N. HUDI, T. KUAN
P1-10 Development of the test capable to reveal level of adhesion between fibreglass rod and coating of composite insulators
I. GUTMAN, A. DERNFALK, P. SIDENVALL
P1-11 High corrosion resistance of ACFR
Y. KONDO
P1-12 Voltage measurement based on inverse piezoelectric effect and fibre grating
Y. HE, Q. YANG T. WANG, G. WANG, H. LIU
P1-13 Integral Equation to Calculate Partial Discharge Characteristics for Asymmetric Electrode Systems
T. OKAMOTO, K. YAMAKAWA, M. YASHIMA, T. TAKAHASHI, H. UEHARA
P1-14 Dielectric tests for 250 kV DC-GIS
T. YASUOKA, Y. ABE, M. SHIIKI, T. KARUBE
P1-15 Air Insulation Test Results of 500kV Double Bi-Pole Transmission Line with Metallic Return Conductor
K. SHIN, G. KWON, J. OH, S. ROH, J. WOO
P1-x1 Effect of Electrode Material on OPGW Direct Lightning Strike
Y. HUANG, X. YAO, J. SUN, X. ZHU, J. CHEN
P1-x2 The Breakdown Characteristics and Synergistic Effects of C4F7N/CO2 Gas Mixtures under Lightning Impulse
J. SONG
 

Poster 2 : Category A3, B1, B3, B4, C4

【2nd Floor Lobby】Thursday, 25th April 9:00 ~ 12:50

P2-01 Space Charge Distribution in Double Layered Insulating Materials used for DC Transmission Cable Joint
K. IGUCHI, H. MIYAKE, Y. TANAKA, Y. MURATA, Y. INOUE
P2-02 Research on Breaking Test Method of Mechanical DC Circuit Breaker
L. LIU
P2-03 Small Amounts of Oil Leakage Detection for Transformer Using Fluorescence Recognition Technology and Field Test
L. LU, S. ICHIMURA, A. YAMAGISHI, T. ROKUNOHE, J. WADA, G. UETA
P2-04 Integrating Sustainability and Innovation in HV Substation Design
M. SIDDIQUI
P2-05 Development of 550 kV GIS transportable as one bay unit
T. SUNAZUKA, H. TAKAO, M. SHIIKI, H. SUGIYAMA, W. ISHIKAWA, S. TSUKAO
P2-06 Recent HVDC projects – interconnection of countries, off-shore wind connection and Back-to-Back systems
A. KRONTIRIS, A. NISHIOKA
P2-07 VSC HVDC Applications – Enabling High Reliability Transmissions
P. LUNDBERG, S. INOUE, A. NISHIOKA
P2-08 Reproduction of measured high-current surge characteristics of grounding electrodes with the finite difference time domain method
F. ZHANG, Y. BABA, N. NAGAOKA
P2-09 FDTD simulation of electromagnetic fields associated with lightning to a transmission line
Y. NASU, M. FUKUYAMA, Y. BABA, T. TSUBOI, S. OKABE
P2-10 Transient electromagnetic and thermal analysis of a lightning-impulse-applied transmission line surge arrester using the FDTD method
R. TSUGE, H. SAITO, Y. BABA, H. KAWAMURA, N. ITAMOTO
P2-11 Effect of Earth Surface on Lightning Electromagnetic Pulse Propagation
A. YAMANAKA, N. NAGAOKA, Y. BABA, M. SAITO
P2-12 Novel and necessary structure of overall on-line monitoring for power system - relation layer
L. YANG
P2-13 Investigation on current breaking phenomena for EHV transmission system with phase-shifter
Y. KIKUCHI, M. KAWASAKI, R. KOYAMA, J. KIDA, N. TAKIURA, A. YAGUCHI, M. TASHIRO, I. WAKAMATSU, M. SUZUKI, S. HOSOI